Operation of the fans

The condenser fan needs to run at the same time as the compressor in order to promote circulation cooling. If the compressor is running but the fan is not operating, there may be a fault with the wiring or the actual fan motor.

PLEASE NOTE!

On some cold room units, there may be two condenser fans. If you see one fan not working, this may be because it may be on a differential pressure switch which means that it will only operate when the pressure switches are activated.

 

Noises and humming

Whining, clunking or knocking noises coming from the fan could be caused by damaged bearings. The fan will eventually fail and should be replaced when possible.



More in this Category

Travel Agents

Troubleshooting guides

Article
Course by Frost Chill Cooling
Travel Agents

Compressor

Article
Compressor by Stavros Gazis
Travel Agents

Solenoid Valve

Article
Solenoid Valve by Stavros Gazis
Travel Agents

Defrost system

Article
Defrost system by Stavros Gazis
Travel Agents

Filter Drier

Article
Filter Drier by Stavros Gazis
Travel Agents

Sight Glass

Article
Sight Glass by Stavros Gazis
Travel Agents

Thermostat operation

Article
Thermostat operation by Stavros Gazis
Travel Agents

EVAPORATOR fan motor

Article
EVAPORATOR fan motor by Stavros Gazis
Travel Agents

Evaporator operation

Article
Evaporator operation by Stavros Gazis
Travel Agents

TXV Unit

Article
TXV Unit by Stavros Gazis
Travel Agents

Condenser fan

Article
Condenser fan by Stavros Gazis
Travel Agents

Orifice

Article
Orifice by Stavros Gazis
Travel Agents

Heating Element

Article
Heating Element by Stavros Gazis
Travel Agents

Drain heater

Article
Drain heater by Stavros Gazis
Travel Agents

Suction line drier

Article
Suction line drier by Stavros Gazis
Travel Agents

Accummulator

Article
Accummulator by Stavros Gazis
Travel Agents

CONDENSER fan blade

Article
CONDENSER fan blade by Stavros Gazis
Travel Agents

Interior Lighting

Article
Interior Lighting by Stavros Gazis
Travel Agents

Condenser unit

Article
Condenser unit by Stavros Gazis
Travel Agents

Oil separator

Article
Oil separator by Stavros Gazis
Travel Agents

Heating Sensor

Article
Heating Sensor by Stavros Gazis
Travel Agents

Electrical Wiring

Article
Electrical Wiring by Stavros Gazis
Travel Agents

Rotork Service Valve

Article
Rotork Service Valve by Stavros Gazis
Travel Agents

Compressor starter

Article
Compressor starter by Stavros Gazis
Travel Agents

Compressor PTC/Klixon

Article
Compressor PTC/Klixon by Stavros Gazis
Travel Agents

Compressor capacitor

Article
Compressor capacitor by Stavros Gazis
Travel Agents

HP/LP sensor

Article
HP/LP sensor by Stavros Gazis
Travel Agents

Rest

Article